Chromatography Gas Mass Spectrometry. The vapor stream that exits a gas chromatograph is under pressure sometimes over 5 times greater than atmospheric pressure. High vacuum is achieved by use of a fore pump and a turbomolecular pump. Gas Chromatography-Mass Spectroscopy GC-MS combines the GC and MS techniques to separate and identify organic compounds in mixtures of organic compounds. The Gas ChromatographyMass Spectrometry GCMS instrument separates chemical mixtures the GC component and identifies the components at a molecular level the MS component.
It is one of the most accurate tools for analyzing environmental samples. The stationary phase is a microscopic layer of liquid or polymer absorbed on an inert solid support. In GC the mobile phase is a carrier gas usually an inert gas such as helium or nitrogen. Gas Chromatography Mass Spectrometry GCMS Todays labs need and want more from their chromatography so many have turned to mass spectrometry for greater insights and precise data. High vacuum is achieved by use of a fore pump and a turbomolecular pump. Mass spectra provide information on the molecular weight elemental composition if a high resolution mass spectrometer is used functional groups present and in some cases the geometry and spatial isomerism of the molecule.
The analysis of different unknown mixtures will be performed via high resolution capillary gas chromatography GC coupled with an ion trap detector ITD.
The analysis of different unknown mixtures will be performed via high resolution capillary gas chromatography GC coupled with an ion trap detector ITD. A mass spectrometer is an analytical instrument that produces a beam of gas ions from samples analytes sorts the resulting mixture of ions according to their mass-to-charge mz ratios using electrical or magnetic fields and provides analog or digital output signal. The Agilent GCMS portfolio is based on 40 years of experience in mass spectrometry analysis and provides the tools for laboratories to meet the demands of challenging analyses with confidence. The ITD is a variation of a quadrupole mass spectrometer and is designed to function specifically as a GC detector. Gas chromatography combined with a triple quadrupole mass spectrometry system is referred to as GC-MSMS. Mass spectra provide information on the molecular weight elemental composition if a high resolution mass spectrometer is used functional groups present and in some cases the geometry and spatial isomerism of the molecule.